Page view 4
www.RuggedCom.com
5
RuggedSwitch
®
RSG2200
RuggedSwitch
®
RSG2200
9-Port Managed Gigabit Ethernet Switch, 128-bit Encryption
EMI and Environmental Type Tests
Environmental Type Tests
Test Description Test Levels
IEC 60068-2-1 Cold Temperature Test Ad -40°C, 16 Hours
IEC 60068-2-2 Dry Heat Test Bd +85°C, 16 Hours
IEC 60068-2-30 Humidity (Damp Heat, Cyclic) Test Db 95% (non-condensing), 55°C , 6 cycles
IEC 60255-21-1 Vibration 2g @ (10 - 150) Hz
IEC 60255-21-2 Shock 30g @ 11mS
IEC 61850-3 EMI TYPE TESTS
TEST Description Test Levels Severity Levels
IEC 61000-4-2 ESD
Enclosure Contact +/- 8kV 4
Enclosure Air +/- 15kV 4
IEC 61000-4-3 Radiated RFI Enclosure ports 20 V/m Note 1
IEC 61000-4-4 Burst (Fast Transient)
Signal ports +/- 4kV @ 2.5kHz Note 1
D.C. Power ports +/- 4kV 4
A.C. Power ports +/- 4kV 4
Earth ground ports +/- 4kV 4
IEC 61000-4-5 Surge
Signal ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4
D.C. Power ports +/- 2kV line-to-earth, +/- 1kV line-to-line 3
A.C. Power ports +/- 4kV line-to-earth, +/- 2kV line-to-line 4
IEC 61000-4-6 Induced (Conducted) RFI
Signal ports 10V 3
D.C Power ports 10V 3
A.C. Power ports 10V 3
Earth ground ports 10V 3
IEC 61000-4-8 8 Magnetic Field Enclosure ports
40 A/m continuous, 1000 A/m for 1 s Note 1
1000 A/m for 1 s 5
IEC 61000-4-29
Voltage Dips & Interrupts
D.C. Power ports 30% for 0.1s, 60% for 0.1s, 100% for 0.05s N/A
A.C. Power ports
30% for 1 period, 60% for 50 periods N/A
IEC 61000-4-11 100% for 5 periods, 100% for 50 periods N/A
IEC 61000-4-12 Damped Oscillatory
Signal ports 2.5kV common, 1kV diff. mode@1MHz 3
D.C. Power ports 2.5kV common, 1kV diff. mode@1MHz 3
A.C. Power ports 2.5kV common, 1kV diff. mode@1MHz 3
IEC 61000-4-16 Mains Frequency Voltage
Signal ports 30V Continuous, 300V for 1s 4
D.C. Power ports 30V Continuous, 300V for 1s 4
IEC 61000-4-17 Ripple on D.C. Power Supply D.C. Power ports 10% 3
IEC 60255-5 Dielectric Strength
Signal ports 2kVac (Fail-Safe Relay output) N/A
D.C. Power ports 1.5kV DC N/A
A.C. Power ports 2kVac N/A
IEC 60255-5 H.V. Impulse
Signal ports 5kV (Fail-Safe Relay output) N/A
D.C. Power ports 5kV N/A
A.C. Power ports 5kV N/A
IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS
2
Test Description Test Levels
IEEE C37.90.3 ESD
Enclosure Contact +/-2kV, +/-4kV, +/- 8kV
Enclosure Air +/-4kV, +/-8kV, +/-15kV
IEEE C37.90.2 Radiated RFI Enclosure ports 35 V/m
IEEE C37.90.1 Fast Transient
Signal ports +/- 4kV @ 2.5kHz
D.C. Power ports +/- 4kV
A.C. Power ports +/- 4kV
Earth ground ports3 +/- 4kV
IEEE C37.90.1 Oscillatory
Signal ports 2.5kV common mode @1MHz
D.C. Power ports 2.5kV common, 1kV diff. mode@1MHz
A.C. Power ports 2.5kV common, 1kV diff. mode@1MHz
IEEE C37.90 H.V. Impulse
Signal ports 5kV (Fail-Safe Relay output)
D.C. Power ports 5kV
A.C. Power ports 5kV
IEEE C37.90 Dielectric Strength
Signal ports 2kVac
D.C. Power ports 1.5kV DC
A.C. Power ports 2kVac
Notes: 1. Ruggedcom specified severity levels
2. Meets Class 2 requirements for an all fiber configuration. Class 1 for copper ports.